Pump flow & head calculator
FIELDCALC · 08Convert flow units and water-equivalent head / pressure, and compare flow, head and shaft power at different speeds for the same centrifugal pump.
Practical calculators for motors and machinery.
Built for your workbench, and your phone.
Convert flow units and water-equivalent head / pressure, and compare flow, head and shaft power at different speeds for the same centrifugal pump.
WORKED FIELD EXAMPLE · HYPOTHETICAL
Suppose quotation A states 60 L/min and B states 3.6 m³/h. Entering 60 L/min gives 3.6 m³/h, 0.001 m³/s and approximately 15.8503 US gpm. Those flow figures are equivalent; this alone does not establish matching head, shaft power, materials or installation conditions.
Enter 20 m in water head ↔ pressure mode. The equivalent difference is 1.96133 bar = 196.133 kPa = 0.196133 MPa, approximately 28.4467 psi. Density is fixed at 1,000 kg/m³.
Assume a current point of 2,900 RPM, 60 L/min, 20 m and 1 kW of pump shaft power. The speed-change example gives ratio 1.2, flow 72 L/min (+20%), head 28.8 m (+44%) and shaft power 1.728 kW (+72.8%). US-unit defaults represent the same physical example. This is a same-pump affinity comparison, not a system operating-point or electricity-bill prediction.
1 m³/h = 1,000/60 L/min; 1 US liquid gallon = 3.785411784 L. Imperial gallons are not included. English defaults use US gpm, ft and mechanical hp; all units remain selectable. The underlying physical model is the same in both languages.
Equivalent pressure difference Δp = ρgH, with ρ = 1,000 kg/m³ and g = 9.80665 m/s². Conversion factors: 1 bar = 100,000 Pa; 1 MPa = 1,000,000 Pa; 1 ft = 0.3048 m; 1 psi ≈ 6,894.757293 Pa. Temperature-dependent water density is not modeled.
Total pump head also includes velocity-head and elevation differences between suction and discharge. Do not infer total head from one discharge gauge alone. This converter does not replace system analysis for significant static lift, viscous fluids, oil or hot water.
For r = n₂/n₁: Q₂ = Q₁r, H₂ = H₁r² and P₂ = P₁r³. These approximate corresponding points for the same centrifugal pump, unchanged impeller size and geometry, the same fluid and approximately unchanged efficiency. They are not a direct comparison of different pump models or positive-displacement pumps.
Actual flow is set by the intersection of the changed pump curve and the system curve. Review static head, friction, viscosity, NPSH / cavitation, manufacturer speed limits and motor loading separately. Do not increase VFD frequency based only on this calculation.
No. P₁ is the mechanical power required at the pump shaft at the stated operating point. It is neither motor rated output nor metered electrical input. Motor and drive efficiencies are needed to estimate electricity consumption; the cubic result alone does not establish electrical savings.
These inputs are actual shaft speeds in RPM, not frequency in Hz. Induction-motor slip and controls affect speed. Use manufacturer data or measured RPM for a consistent operating point.
Zero is allowed for simple flow and head conversions. Speed comparison requires positive speed, flow, head and shaft power. Blank, negative or out-of-range values disable valid results and saving.